不断超越,追求完美

效率成就品牌,诚信铸就未来

只有更好的服务,才有更多的用户

  • HD600型SF6气体泄漏报警监控系统-武汉华顶电力

  •           供应深圳火灾报警主机 出口欧洲火灾报警主机 The CK1000 is a 4-zone to 16-zone FACP (Fire Alarm Co*ol Panel), which uses conventional input devices.  The panel accepts water flow devices, two-wire smoke detectors, four-wire smoke detectors, pull stations and other normally-open contact devices. Outputs include four Notification Appliance Circuits (NAC, SOUND1-4), three standard Form-A relays (alarm, trouble and supervisory) and an EIA-485 port to interface with remote annunciators and optional remote relay modules. The FACP is field programmable via the panel keypad.  It also supervises all wiring, AC voltage and battery level.   This series of panels are basically the same in application and operation, their differences are shown in Table 1-1. CK1000 will be described as the example in the following sections.   Table 1-1 FACP Number of Detection Zones Number of Sounder Outputs Output Delay Settings CK1004 4 1 N/A CK1008 8 2 N/A CK1016 16 4 N/A   1.1 Product Features   l       4,8,16 Class B Initiating Device Circuits (IDCs)    All zones accept conventional detectors and any normally open contact device l       Four Class B Notification Appliance Circuits (NACs) l       One Form-A Alarm Relay l       One Form-A Trouble Relay l       One Form-A Supervisory Relay l       3.0 amps of system power l       Max 20 conventional detectors in one zone. l       Auto/Manual mode setting enable walk test. l       Each Zone can be disabled, l       Sound output can be disabled. l       Manual active sound output enabled. l       Able to report short and broken circuit of detection zones. l       Designed with standby batteries and space provision for two sealed lead-acid batteries. l       Testing and disable functions.   AC Power AC90-270 VAC, 50 Hz, 2.3 amps Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation Battery (lead acid only) Maximum Charging Circuit:NormalFlat Charge—27.6V @ 0.8 amp Maximum Charger Capacity: 18 Amp Hour batter Sound Output Device Circuits General Alarm Zones 1 through 16 Operation: All zones Class B Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum) Alarm Current: 15 mA threshold Short Circuit Current: 42 mA maximum MaximumLoopResistance: 100 ohms End-of-Line Resistor: 4.7K, watt DetectorLoopCurrent is sufficient to ensure operation of two alarmed detectors per zone Standby Current: 7.26 mA Three Relays Output Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive) Nonresettable 24 VDC Power Maximum ripple voltage: 10 mVRMS          Operating Voltage nominal 24 volts Total DC current *ailable from this output is up to 500 mA Recommended maximum Standby current is 150 mA 标签: 多线火灾 出口火灾   多线火灾报警主机 出口火灾报警器   深圳市火灾报警主机   深圳市火灾报警主机厂家
    [多线火灾报警主机 出口火灾报警器] 深圳市火灾报警主机厂家
    HD600型SF6气体泄漏报警监控系统-武汉华顶电力
  • 企业信息
  • 状态:匆匆过客
  • 核实:        
  • IP属地:湖北
  • 联系方式
  • 联系人:---
  • 座机:---
  • 手机:---
  • 地址:---